Features: |
![]() Shell code:H033 |
|
Model |
HDR-60-5 |
HDR-60-12 |
HDR-60-15 |
HDR-60-24 |
HDR-60-48 | |
|
OUTPUT |
DC Voltage |
5V |
12V |
15V |
24V |
48V |
|
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% | |
|
Rated Current |
6.5A |
4.5A |
4A |
2.5A |
1.3A | |
|
Current Range |
0-6.5A |
0-4.5A |
0-4A |
0-2.5A |
0-1.3A | |
|
Rated Power |
32.5W |
54W |
60W |
60W |
62.4W | |
|
Ripple & Noise |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
150mVp-p | |
|
DC Adjustment Range |
-5%,+10% |
-8%,+10% |
±10% |
±10% |
±10% | |
|
Setup, Rise Time |
100ms,30ms/230VAC at full load200ms,30ms/115VAC at full load | |||||
|
Hold Time |
100ms/230VAC23ms/115VAC at full load | |||||
|
INPUT |
Voltage Range |
88~264 VAC47~63 Hz; selected by switch 124~370VDC | ||||
|
AC Current |
1.2A/115 V 0.8A/ 230 V | |||||
|
Efficiency |
76% |
82% |
83% |
84% |
85% | |
|
Inrush Current |
Cold start 20A/115V 40A/230V | |||||
|
Leakage Current |
<1mA/240VAC | |||||
|
PROTECTION |
Over Load |
105%~160% | ||||
|
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
|
Over Voltage |
115%~135% | |||||
|
Protection type: hiccup mode,recovers automatically after fault condition is removed | ||||||
|
ENVIRONMENT |
Working Temp., Humidity |
-20℃~+60℃;20%~90 %RH | ||||
|
Storage Temp., Humidity |
-40℃~+85℃;10%~95 %RH | |||||
|
Vibration |
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |||||
|
SAFETY |
Withstand Voltage |
I/P-O/P: 3KVAC | ||||
|
Isolation Resistance |
I/P-O/P: 100M Ohms / 500VDC | |||||
|
STANDARD |
Safety Standard |
Design refer to UL60950-1,TUV EN60950-1,EN50178 | ||||
|
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204, | |||||
|
OTHERS |
Weight |
0.26Kg | ||||
|
Packing |
45pcs/13Kg/1.22CUFT | |||||
|
NOTE |