Model |
S-100F-5 |
S-100F-7.5 |
S-100F-12 |
S-100F-15 |
S-100F-24 |
S-100F-27 |
S-100F-48 | ||||
|
Output |
DC Voltage |
5V |
7.5V |
12V |
15V |
24V |
27V |
48V | |||
|
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% | ||||
|
Rated Current |
20A |
13.5A |
8.5A |
6.7A |
4.5A |
3.5A |
2.2A | ||||
|
Current Range |
0-20A |
0-13.5A |
0-8.5A |
0-6.7A |
0-4.5A |
0-3.5A |
0-2.2A | ||||
|
Rated Power |
100W |
101W |
102W |
100.5W |
108W |
94.5W |
105.6W | ||||
|
Ripple & Noise |
100mVp-p |
125mVp-p |
125mVp-p |
125mVp-p |
150mVp-p |
150mVp-p |
150mVp-p | ||||
|
DC Voltage Adj. Range |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% | ||||
|
Setup, Rise, Hold time |
1s,30ms,15ms full load | ||||||||||
|
Input |
Voltage Range |
88~132 VAC/176~264VAC 47~63 Hz; 248~370VDC | |||||||||
|
AC Current |
3.15A/115 V 1.5A/ 230 V | ||||||||||
|
Efficiency |
76% |
78% |
80% |
81% |
83% |
83% |
84% | ||||
|
Inrush Current |
Cold start 30A/115V 60A/230V | ||||||||||
|
Leakage Current |
<1 mA/240VAC | ||||||||||
|
Protection |
Over Load |
115%~165% | |||||||||
|
Protection type:shut down o/p voltage,recovers automatically after fault condition is removed | |||||||||||
|
Over Voltage |
115%~135% | ||||||||||
|
Protection type:hiccup mode,recovers automatically after fault condition is removed | |||||||||||
|
Environment |
Working Temp. & Humidity |
-10℃~+60℃;20%~90 %RH | |||||||||
|
Storage Temp. & Humidity |
-20℃~+85℃;10%~95 %RH | ||||||||||
|
Vibration |
10~500Hz,2G 10min./1 cycle,period for 60min,each along X,Y,Z axes | ||||||||||
|
Safety |
Withstand Voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||
|
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||||||||||
|
Standards |
Safety Standard |
Design refer to UL1012 TUV EN60950 | |||||||||
|
EMC Standard |
Design refer to EN55022,EN61000-3-2,-3;EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 | ||||||||||
|
Others |
Weight |
0.65Kg | |||||||||
|
Packing |
30pcs/19.8Kg/1.22CUFT | ||||||||||
|
Remarks |
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature. 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ&47μparallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equpment must be re-confirmed that it still meets EMC directives. 5. Concrete output current see Derating Curve. | ||||||||||